174 | | |
175 | | (1)ERR_ACT = 1 is recommended when running global long-term simulations. Under this option, mass balance closure is checked for all biogeochemical processes but only at the highest level thus stomate.f90 and stomate_lpj.f90. Although the mass balance checks are not very expensive in terms of computer time, skipping the numerous lower level checks is expected to save some time. Under this option the mass balance error is only written to the history file. No information is provided in which subroutine the problem occurred. |
176 | | (2)ERR_ACT = 2 is recommended when developing and testing the model. Now the mass balance is explicitly checked in stomate.f90, stomate_lpj.f90 and all its subroutines. Under this option the mass balance error is written to the history file and if the mass balance is not closed, the warning message will indicate in which subroutine the problem likely originated. |
177 | | (3)ERR_ACT = 3 is recommended when having a problem with mass balance closure. The mass balance is explicitly checked in stomate.f90, stomate_lpj.f90 and all its subroutines. If a mass balance occurs, the model is stopped. |
| 174 | |
| 175 | 1 - ERR_ACT = 1 is recommended when running global long-term simulations. Under this option, mass balance closure is checked for all biogeochemical processes but only at the highest level thus stomate.f90 and stomate_lpj.f90. Although the mass balance checks are not very expensive in terms of computer time, skipping the numerous lower level checks is expected to save some time. Under this option the mass balance error is only written to the history file. No information is provided in which subroutine the problem occurred. |
| 176 | |
| 177 | 2 - ERR_ACT = 2 is recommended when developing and testing the model. Now the mass balance is explicitly checked in stomate.f90, stomate_lpj.f90 and all its subroutines. Under this option the mass balance error is written to the history file and if the mass balance is not closed, the warning message will indicate in which subroutine the problem likely originated. |
| 178 | |
| 179 | 3 - ERR_ACT = 3 is recommended when having a problem with mass balance closure. The mass balance is explicitly checked in stomate.f90, stomate_lpj.f90 and all its subroutines. If a mass balance occurs, the model is stopped. |