Changeset 432
- Timestamp:
- 06/15/16 00:12:01 (8 years ago)
- Location:
- configs/dcmip2016/RUNS/BAROCLINIC_WAVE/dry
- Files:
-
- 4 edited
Legend:
- Unmodified
- Added
- Removed
-
configs/dcmip2016/RUNS/BAROCLINIC_WAVE/dry/field_def.xml
r425 r432 1 1 <field_definition level="1" enabled=".TRUE." operation="instant"> 2 2 3 <field_group id="standard_output" freq_op="36ts" freq_offset="35ts">3 <field_group id="standard_output"> 4 4 5 5 <field id="timestep" grid_ref="scalar" unit="s"/> … … 16 16 <field id="phis" /> 17 17 <field id="precl" /> 18 18 <field id="Q1_col_int" /> 19 <field id="Q2_col_int" /> 19 20 <field id="ps_init" /> 20 21 -
configs/dcmip2016/RUNS/BAROCLINIC_WAVE/dry/filedef_dcmip2016.xml
r425 r432 1 <file_definition> 1 <file_definition> 2 2 3 3 <file id="output_dcmip2016_native" enabled=".TRUE." output_freq="3h" sync_freq="3h" output_level="10" description="Dry baroclinic wave" > … … 28 28 <field field_ref="q4" name="Q1" long_name="Single chlorine mixing ratio" unit="kg/kg"/> 29 29 <field field_ref="q5" name="Q2" long_name="Chlorine gas mixing ratio" unit="kg/kg"/> 30 <field field_ref="Q1_col_int" name="Q1_col_int" long_name="Single chlorine column integrated mixing ratio" unit="kg/m2"/> 31 <field field_ref="Q2_col_int" name="Q2_col_int" long_name="Chlorine gas column integrated mixing ratio" unit="kg/m2"/> 30 32 <field field_ref="u850" name="U850" long_name="Zonal wind at 850 hPa" unit="m/s"/> 31 33 <field field_ref="v850" name="V850" long_name="Meridional wind at 850 hPa" unit="m/s"/> -
configs/dcmip2016/RUNS/BAROCLINIC_WAVE/dry/job_ys
r425 r432 10 10 #BSUB -o dynamico.%J.out # output file name in which %J is replaced by the job ID 11 11 #BSUB -e dynamico.%J.err # error file name in which %J is replaced by the job ID 12 #BSUB -q small # queue 12 ##BSUB -q small # queue 13 #BSUB -q tutorial # queue 13 14 14 15 #run the executable … … 20 21 module load totalview/8.14.0-16 21 22 22 #totalview -mpi "poe - Linux" -np 40 ../../ DYNAMICO/bin/icosa_gcm.exe23 mpirun.lsf ../../ DYNAMICO/bin/icosa_gcm.exe23 #totalview -mpi "poe - Linux" -np 40 ../../../DYNAMICO/bin/icosa_gcm.exe 24 mpirun.lsf ../../../DYNAMICO/bin/icosa_gcm.exe 24 25 #mpirun.lsf -cmdfile ./cmd_file.txt -
configs/dcmip2016/RUNS/BAROCLINIC_WAVE/dry/run.def
r425 r432 14 14 15 15 # Mesh optimisation : number of iterations : integer (default=0) 16 optim_it = 10016 optim_it = 2000 17 17 18 18 # Sub splitting of main rhombus : integer (default=1) … … 27 27 28 28 # Dissipation time for grad(div) : real (default=5000) 29 tau_graddiv = 800029 tau_graddiv = 2000 30 30 31 31 # Exponent of grad(div) disspation : integer (default=1) … … 33 33 34 34 # Dissipation time for curl(curl) : real (default=5000) 35 tau_gradrot = 800035 tau_gradrot = 2000 36 36 37 37 # Exponent of curl(curl) disspation : integer (default=1) … … 39 39 40 40 # Dissipation time for div(grad) : real (default=5000) 41 tau_divgrad = 800041 tau_divgrad = 2000 42 42 43 43 # Exponent of div(grad) disspation : integer (default=1) … … 66 66 67 67 68 itau_physics= 268 itau_physics=3 69 69 physics=dcmip2016 70 70 #physics_dcmip2016=moist_baroclinic
Note: See TracChangeset
for help on using the changeset viewer.